C100 Installation Guide
(1) Ventilation is convection via vents at top and bottom of front panel. Do not obstruct vents – refer to
Appendix F for additional information.
C
-SB Micamp Rack
Parameter Condition Value Unit Notes
H
eight: 14 U
620 mm
Width: 19 in
Case w/o rack ears 432 mm
Depth 300 mm
W
eight Rack with 1 PSU unit 19 Kg No I/O cards
Each micamp/output card 1.7 Kg
Additional PSU 5.8 Kg
Heat Dissipation (1) 380 W Max
Voltage Range 90 - 255 V AC only
Current: Total @ Voltage Range 10.0 - 3.9 A Worst case with max. I/O
Fusing: 1.25" 6.3(T) A Each input
Noise Fanless
Connectors: Mains in IEC Male
Mains out (x2) IEC Female Unswitched
Mic in XLR 3-pin female Pin 2 hot
Insert send out 25-pin D-type male
Audio I/O Duplex LC fibre optic
Network RJ45